Kepler-Sternwarte Linz
After some initial problems (see below), the lightmeter started continuous sky monitoring on 2009-04-21.
On 2014-06-29 the Windows PC running Jörg Weingrill's Skysensor-Software has been replaced by a Laptop running the Lightmeter Software under Unbuntu (see below). The Station code has been changed from AT_LINZ_1 to AT_Linz_2 on that occasion.
Link to the old station-page: http://kuffner-sternwarte.at/hms/wiki/index.php5?title=Kepler-Sternwarte_Linz --GW (talk) 10:52, 30 June 2014 (CEST)
Contents
Preliminary Calibration
Accoring to Günther Wuchterl, the preliminary calibration for the Lightmeter #3 is:
- For < 1 lux: Lux = 3E-7 * counts (calibrated with a hand-held luxmeter)
- For > 1 lux to at least 20'000 lux: Lux = 2E-6 * (counts+exp(counts/8.7E4))
The latter is precise to ±10% on Lightmeter #2.
Final Calibration
Results of final calibration (described in detail here: Calibration example Linz):
X = c ( b (a exp (n(1+dT)/a) - 1) + n ) n ... counts (sensor output)
X ... physical quantity (total radiation in [W/m²] or horizontal illumination [Lux])
a = 1.2835e+05, b = 1.6468e-02, c = 2.5778e-09, d = 3.4726e-03 W/m² a = 1.2835e+05, b = 1.6468e-02, c = 3.1887e-07, d = 3.4726e-03 Lux
Background X0 = 6.741 mlx
Problems
There were two problems with Lightmeter in Linz. First, switching the fluorescent lamps on or off inside the observatory building crashes the Luxmeter driver. Second, due to the cable extension needed, the USB connection was unstable. A workaround for the first problem can be achived by setting up the software so that PC reboots every time the driver crashes. The solution for the second problem was found in using a USB-Extender USB-RJ45, which uses a 10m network cable to extend the original Lightmeter cable to the PC, and to use Jörg Weingrill's Skysensor-Software, which reboots the PC in case of USB errors.
For a more detailed description of the problems (in German language), see Lightmeter-Driver#USB-Fehler am Linzer Luxmeter.
Sometimes, there is apparently a problem with the USB connection, no data is recorded, the Skysensor-Software does display "Error" in the status line, but still does not reboot the PC. On several occasions, this has gone unnoticed for several days, leading to long gaps in the measurements. To avoid this, we have installed a scheduled task which reboots the PC every day at 6:00, 12:00, 18:00 and 23:55 local time.
Replacement of the Computer
Due to increasing downtime of the Lightmeter, the PC runnig Jörg Weingrill's Skysensor-Software under Windows XP has been replaced on 2014-06-29 by a Laptop running the Lightmeter Software under Unbuntu. The laptop was set up by Felix Linhardt. The Station code has been changed from AT_LINZ_1 to AT_LINZ_2 on that occasion.
The original sensor (Mark 2.2) is still in use. Also, data upload and clock check is still done manually at more or less regular intervals, about one in a month.
--HerbertRaab (talk) 08:52, 1 July 2014 (CEST)
Data on public lighting in Linz
According to this article from Ausgust 2010, 20'624 luminaries with a total of 23'206 lamps are used for public lighting in Linz (189'311 inhabitants, as of Jaunuary 2010). The total power comsumption for the public lighting is 2.01 Megawatts. Not included in these figures is, of course, the public lighting of neighbouring municipalities. (Note that the Kepler observatory is located close to the western city limit of Linz, towards the city of Leonding [24.976 inhabitants]). --HerbertRaab 09:01, 3. Sep. 2010 (UTC)
Results
- Query data at the GAVO data center (Change parameters as necessary. Don't foget to select 'AT_LINZ_1' or 'AT_LINZ_2' for the Staion ID.)
- Directory listing (AT_LINZ_1, from 2009-04-21 to 2014-06-30)
- Directory listing (AT_LINZ_2, from 2014-06-30)